Home › Products › Three-phase motors

I-MAK Three-Phase Asynchronous Motors

IEC frame motors from 0.12 to 450 kW, in 2, 4, 6 and 8 pole versions.

Three-phase asynchronous motors in IEC frame sizes, for I-MAK geared motors or to drive your own machine. Genuine I-MAK motors, supplied and supported from Silsden, West Yorkshire.

Get a priceSend us your motor nameplate
I-MAK three-phase asynchronous motor

450kW

Motor powerFrom 0.12 kW upwards.

16frame sizes

IEC frame sizesFrom frame 63 up to frame 400.

IE3

Efficiency classI-MAK’s standard; the smallest sizes are IE1 or IE2.

IP55

ProtectionAs standard, with IP54, IP56, IP65 or IP66.

Overview

I-MAK three-phase motors: one range from 0.12 to 450 kW

I-MAK’s three-phase asynchronous motors run from 0.12 to 450 kW, in IEC frame sizes from 63 up to 400. They are the motors I-MAK fits to its geared motors, and they are also available on their own, foot or flange mounted.

As standard, a motor is wound for 400 V 50 Hz, with IP55 protection and class F insulation, rated for S1 continuous duty in an ambient of 0 to 40 °C. Other voltages and frequencies, IP54, IP56, IP65 or IP66 protection and class B or H insulation are available to order.

Options include brakes, encoders, thermistors and winding heaters, an external cooling fan, a canopy, backstop bearings and a double shaft. Explosion proof and single-phase motors are available to order.

Advanced Drives is the official UK supplier of I-MAK gearboxes and motors, and supplies I-MAK motors on their own or as part of a geared motor.

Which I-MAK motor?

Choose a geared motor by its gearbox

Key advantages

Why choose an I-MAK motor

0.12 to 450 kW

One range of IEC frame motors, from frame 63 up to frame 400.

2, 4, 6 or 8 poles

Pole numbers to suit the speed you need, depending on the frame size.

IE3 as standard

IE3 is I-MAK’s standard class, with IE4 as an option; the smallest sizes are IE1 or IE2.

IP55 as standard

IP55 protection and class F insulation, with IP54, IP56, IP65 and IP66 to order.

Foot or flange mounted

B3, B5, B14 and B35 mountings, and a NEMA C-face connection.

Wide option list

Brakes, encoders, thermal protection, heaters, an external fan and explosion proof versions.

Technical data

I-MAK motor technical specifications

IEC frame sizes from 63 to 400, each with the pole numbers shown. The power figures are from I-MAK’s performance tables for 4-pole (1,500 rpm) and 6-pole (1,000 rpm) motors; ask us for 2-pole and 8-pole ratings.

IEC frame size Poles 4-pole power (kW) 6-pole power (kW)
63 2, 4 0.12 to 0.18 Not listed
71 2, 4, 6, 8 0.25 to 0.37 0.18 to 0.25
80 2, 4, 6, 8 0.55 to 0.75 0.37 to 0.55
90 2, 4, 6, 8 1.1 to 1.5 0.75 to 1.1
100 2, 4, 6, 8 2.2 to 3 1.5
112 2, 4, 6, 8 4 2.2
132 2, 4, 6, 8 5.5 to 7.5 3 to 5.5
160 2, 4, 6, 8 11 to 15 7.5 to 11
180 2, 4, 6, 8 18.5 to 22 15
200 2, 4, 6, 8 30 18.5 to 22
225 2, 4, 6 37 to 45 30
250 2, 4, 6 55 37
280 2, 4, 6 75 to 90 45 to 55
315 2, 4, 6 110 to 200 75 to 132
355 2, 4, 6 250 to 400 160 to 355
400 4 450 Not listed
Common to every size I-MAK three-phase motors
Type Three-phase asynchronous, in IEC frame sizes
Power 0.12 to 450 kW
Rated speed 4-pole 1,315 to 1,490 rpm; 6-pole 835 to 995 rpm
Supply 400 V 50 Hz as standard; other voltages and frequencies to order
Mounting B3, B5, B14 and B35, or a NEMA C-face connection
Protection IP55 as standard; IP54, IP56, IP65 and IP66 options
Insulation Class F as standard; class B or H options
Efficiency IE3 standard on I-MAK geared motors, IE4 as an option; I-MAK’s tables class each size as IE1, IE2, IE3 or IE4, so ask us for the class of your motor
Duty S1, continuous
Ambient temperature 0 to 40 °C as standard; ask us outside this range
Terminal box Position KP1 and cable entry A as standard; KP1 to KP4 and A to D available

Power and speed figures are from the motor performance tables in the I-MAK ADK and ADS catalogue 2024, Rev.00, reprinted unchanged in the IR catalogues 2024 and 2026; standard features and options are from the I-MAK IR catalogue 2024, Rev.00, and frame sizes and pole numbers from I-MAK’s motor product data. The 1.5 kW 6-pole motor, printed as 10L6a in I-MAK’s tables, is shown under frame 100, which we are confirming with I-MAK.

Options

Options and configurations

Options are added to the order, so a replacement motor can be matched exactly.

Brakes

A brake with or without its own cooling fan, a hand release or a double brake, for 24 V DC or 220 V AC.

Encoders

Rotary encoders from 100 to 2,048 pulses per revolution.

Thermal protection

A PTC thermistor, a bimetallic thermostat or a PT 100 sensor, and 110 V or 220 V winding heaters.

Cooling fan

An external fan for 24 V DC, 230 V AC or 380 V AC, or a motor without a fan. A canopy is also available.

Bearings

Bearings for hot or cold environments, insulated bearings, greasing nipples, and backstop bearings for either direction.

Supply and protection

Special voltages and frequencies, IP54, IP56, IP65 or IP66 protection, and class B or H insulation.

Shafts and mounting

B3, B5, B14 or B35 mounting, a NEMA C-face connection, or a double shaft motor with a special shaft.

Special motors

Explosion proof, single-phase and torque motors, and synchronous reluctance motors, to order.

Applications

Where I-MAK motors work

I-MAK motors drive I-MAK geared motors across the range, and they can drive your own machinery too. Tell us what the motor drives and how it runs, and we will match the motor and its options.

Motors and geared motors crated for dispatch

Geared motors

The standard motor on I-MAK helical, bevel, parallel shaft and worm geared motors

Replacement motors

A like-for-like motor for an existing geared motor, matched from the nameplate

Brake motors

Drives that need a motor brake, with a hand release option

Explosion proof

Explosion proof motors to order, with certification confirmed by I-MAK for your site

Dusty or wet sites

IP65 or IP66 protection, winding heaters and a canopy

Running at variable speed? Tell us how the motor will be controlled and we will check the motor and its options. Our guide to variable frequency drives covers the basics.

Downloads

I-MAK motor downloads

I-MAK publishes its motor data in its geared motor catalogues. No forms, no sign-up.

IR series catalogue

2026, Rev.01 · Motor options and performance tables · PDF

Download

Gearboxes and Drives brochure

2025 · Motor frame sizes, poles, protection and mountings · PDF

Download

Operating guide

General I-MAK operating guide, 2024 · Oil and maintenance, in four languages · PDF

Download

Online configurator

I-MAK iGuide, for choosing a gearbox online

Open

Dimension drawing

For your exact size and options · On request

Ask us

Can’t find it?

Need the drawing for your exact motor?

Send us the motor code from the nameplate, or the power, speed and mounting, and we will send the right drawing.

Replacing a motor

Replacing an existing I-MAK motor

Every motor carries a nameplate with its power, speed and voltage. Send us those, with a few photos, and we will match the replacement.

Read the motor code

An I-MAK motor code gives the IEC frame size, such as 132, the frame length, S, M or L, and the number of poles, such as 4. In I-MAK’s tables a final letter follows, as in 132M4a.

What to send us

The power, speed, voltage, frequency and serial number from the nameplate, photos of the nameplate, shaft, flange or feet and terminal box, and what the motor drives.

Mounting

Tell us whether the motor is foot mounted (B3), flange mounted (B5 or B14) or both (B35), and where the terminal box sits.

Replacing another make

We can supply an I-MAK motor in the same IEC frame size to replace many other makes. Send us the nameplate details and the shaft and flange dimensions, and we will check the fit.

Spares and repairs

Ask us for spares such as brakes, fans and bearings. Need a repair rather than a replacement? Call us and we will talk it through.

Motor code

How to read an I-MAK motor code

  1. Frame size: the IEC frame, from 63 to 400, such as 132
  2. Frame length: S, M or L, such as M
  3. Poles: 2, 4, 6 or 8, such as 4 for 1,500 rpm
  4. Final letter: a, b, c or d, as printed in I-MAK’s tables, such as 132M4a
  5. In a geared motor: the motor follows the gearbox, such as IRA M 83 – 132 M 4
  6. Options: after the slash, such as BR (brake), E (encoder) and CF (external fan)

Let’s find your motor

Looking for an I-MAK motor or a price?

We just need three details.

Replacing one? Send us the details from the motor nameplate and a photo, and we will work from those.

1

Power and speed

Power in kW, and the speed or the number of poles.

2

Frame and mounting

The IEC frame size, if you know it, and B3, B5, B14 or B35 mounting.

3

Supply and duty

Voltage and frequency, protection, and how the motor runs, including any variable speed use.

Email us your detailsCall +44 (0)1535 655151

Prefer us to call you? Request a callback.

FAQs

I-MAK motor questions

Anything else? Call +44 (0)1535 655151 or email sales@advanced-drives.com.

From 0.12 kW to 450 kW, in IEC frame sizes from 63 up to 400. I-MAK’s performance tables give 4-pole motors from 0.12 to 450 kW and 6-pole motors from 0.18 to 355 kW.

IE3 is the standard class on I-MAK geared motors, with IE4 as an option. I-MAK’s performance tables class each motor size as IE1, IE2, IE3 or IE4, so tell us the power and poles and we will confirm the class of your motor.

Foot mounting (B3), flange mounting (B5 or B14), and foot and flange together (B35), plus a NEMA C-face connection. Tell us the mounting and the terminal box position when you order.

Tell us how the motor will be controlled, the speed range and the load, and we will check the motor and its options with I-MAK. An external cooling fan, special frequency windings and encoders are all available.

400 V 50 Hz, IP55 protection and class F insulation, for an ambient of 0 to 40 °C. Other voltages and frequencies, IP54, IP56, IP65 or IP66 protection and class B or H insulation are available to order.

Yes. Brakes are available with or without their own cooling fan, with a hand release, or as a double brake, for 24 V DC or 220 V AC. Tell us the braking torque you need and how often the motor stops.